IMPLEMENTATION OF FUZZY LOGIC BASED TEMPERATURE-CONTROLLED HEAT EXCHANGER
DOI:
https://doi.org/10.4314/njt.291.146Keywords:
Heat exchanger, Fuzzy logic controller, Proportional Integral, Derivative ControlAbstract
This paper discusses the performance analysis of a heat exchanger using simulations for an Adaptive Network based Fuzzy Inference System toolbox developed with MATLAB. The plant transfer function is derived based on process reaction curve obtained from a heat exchanger pilot plant and then the model is used to represent the heat exchanger throughout the analysis. This research then compares the control performance of PID (Proportional Integral and Derivative) and Fuzzy logic controllers. Conclusions are made based on these control performances. The results show that the control performance for a Fuzzy controller is quite similar to PID controller but comparatively gives a better response.Downloads
Issue
Section
License
The contents of the articles are the sole opinion of the author(s) and not of NIJOTECH.
NIJOTECH allows open access for distribution of the published articles in any media so long as whole (not part) of articles are distributed.
A copyright and statement of originality documents will need to be filled out clearly and signed prior to publication of an accepted article. The Copyright form can be downloaded from http://nijotech.com/downloads/COPYRIGHT%20FORM.pdf while the Statement of Originality is in http://nijotech.com/downloads/Statement%20of%20Originality.pdf
For articles that were developed from funded research, a clear acknowledgement of such support should be mentioned in the article with relevant references. Authors are expected to provide complete information on the sponsorship and intellectual property rights of the article together with all exceptions.
It is forbidden to publish the same research report in more than one journal.